Blackcomb Series 5.0
- Colour user interface with full diagnostics and warnings including QR codes
- Full customization available as an option (language, home screen, phone, web, QR codes, etc.)
- New axial flow, 304 stainless steel reactors, fully polished, designed & manufactured to ASME pressure vessel standard
- Systems include integral UV sensor port for future upgradeability (simply purchase optional UV sensor module to convert system into a fully UV monitored system)
- Flow rates stated at 95% UVT at a dose of 30mJ/cm2
- User friendly bayonet style lamp connector (quick ¼ turn removal with no extra tools needed)
- True gland seal retaining nut with positive stop
- Reliable, industry proven, proprietary low pressure (LP) coated UV lamps with ceramic bases for durability and a 9,000 hour life (1 year)
- Constant current electronic controller (one controller for all systems) in a splash-proof case, fully potted ballast virtually eliminates common water damage issue
Control Your Own Water Quality!
If you are unsure of the microbiological quality of your source water or if you are looking for additional security from your municipal water source, then LUMINOR has the solution in the BLACKCOMB5.0 series of residential UV systems.
UV technology is proven to control microbiological (bacteria & virus) issues in water including E.coli, Cryptosporidium and Giardia lamblia.
Truely modular in design, BLACKCOMB5.0 provides easy upgradeability in the future. Incorporating true “plug-and-play” technology, conversion to a UV monitor is a quick and simple process. A robust full colour controller displays complete system status, lamp countdown, warnings, and a QR code that allows the homeowner to use their smartphone to obtain lamp replacement information or to view service videos! BLACKCOMB incorporates technology that has never been seen in a UV system until now!
Available Systems
Point-of-Entry (POE)
- LB5-032 series, for flow rates of 12 lpm (3 gpm)
- LB5-062 series, for flow rates of 23 lpm (6 gpm)
- LB5-102 series, for flow rates of 41 lpm (11 gpm)
- LB5-152 series, for flow rates of 57 lpm (15 gpm)
- LB5-202 series, for flow rates of 79 lpm (21 gpm)
BLACKCOMB 5.0, Residential UV Systems, UV Monitored | |||||
Model | LB5-032 | LB5-062 | LB5-102 | LB5-152 | LB5-20 |
Flow Rate (@16mJ/cm2) |
6 GPM | 11 GPM | 20 GPM | 30 GPM | 39 GPM |
23 lpm | 41 lpm | 77 lpm | 114 lpm | 150 lpm | |
1.4 m3/hr | 2.5 m3/hr | 4.6 m3/hr | 6.8 m3/hr | 8.9 m3/hr | |
Flow Rate (@30mJ/cm2) |
3 GPM | 6 GPM | 11 GPM | 15 GPM | 21 GPM |
11.4 lpm | 22.7 lpm | 41 lpm | 57 lpm | 79 lpm | |
0.7 m3/hr | 1.4 m3/hr | 2.5 m3/hr | 3.4 m3/hr | 4.8 m3/hr | |
Flow Rate (@40mJ/cm2) |
2.4 GPM | 4.4 GPM | 8.3 GPM | 12 GPM | 16 GPM |
9.1 lpm | 17 lpm | 31 lpm | 45.4 lpm | 59 lpm | |
0.5 m3/hr | 1.0 m3/hr | 1.9 m3/hr | 2.7 m3/hr | 3.6 m3/hr | |
Port Size | ½”MNPT | ¾”MNPT | ¾”MNPT | 1”MNPT | 1”MNPT |
Electrical | 90-265V/50-60Hz. | ||||
Plug Type | American, Nema 5/15, 3 wire for all 110V systems, “1” suffix (i.e. LB5-101) European, CEE 7/7, 3 wire for all 230V systems, “2” suffix (i.e. LB5-102) British Standard, BS 1363, 3 wire for all 230V systems, “3” suffix (i.e. LB5-103) Australian/New Zealand, AS/NZ 3112, 3 wire for all 230V systems, “4” suffix (i.e. LB5-104) |
||||
Lamp Watts | 15 | 22 | 39 | 50 | 42 |
Power (Watts) | 20 | 30 | 49 | 62 | 51 |
Chamber Material |
304 Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||||
Reactor Dimensions |
2.5 x 14.3” (6.4 x 36.4 cm) |
2.5 x 21.3” (6.4 x 54.2 cm) |
2.5 x 35.2” (6.4 x 89.5 cm) |
2.5 x 40.0” (6.4 x 101.6 cm) |
3.5 x 36.1” (8.9 x 91.7 cm) |
Controller Dimensions |
6.8 x 3.6 x 3” (17.2 x 9.2 x 7.6 cm) | ||||
Operating Pressure |
0.7-10.3 bar (10-150 psi) | ||||
Operating Water Temperature |
2-40° C (36-104° F) | ||||
UV Monitor Port | No | Yes (optional UV sensor module sold separately) | |||
Solenoid Output | Yes (but requires optional solenoid module) (activated on lamp failure) | ||||
Dry Contacts | Yes (but requires optional remote alarm module) | ||||
4-20mA Output | Yes (but requires optional 4-20mA module) | ||||
Lamp Change Reminder (audible & visual) | Yes | ||||
Lamp Out Indicator (audible & visual) |
Yes |